39
„BabyCall“ – Automatic call
BabyCall number Function No.: 280
If is programmed as FXO gateway, parameter defines a number
to be dialed for the automatic call function. If this item is blank, the function is
disabled.
interfaces FXO and FXS are connected and dialing to PSTN over FXO interface is
possible.
Setting options: 0-20 characters (0-9,*,#,+)
Default setting: blank
BabyCall timeout [s] Function No.: 281
If is programmed as FXO gateway, parameter defines time
between line Off-Hook and automatic call beginning (if enabled). During this
timeout waits for dialing that cancels the automatic call. You
can make standard call if the BabyCall function is enabled.
Setting options: 0-255 s
Setting step: 1 s
Default setting: 0 s
Mobility extension FLASH
Mobility Extension FLASH DTMF code Function No.: 240
Fill in DTMF code to enable GSM FLASH function. If receive
DTMF dialing corresponding to filled code during GSM - FXO call, it generates
FLASH to FXO interface.
Setting options: 0-4 characters (0-9,*,#)
Default setting: blank
FLASH length [ms] Function No.: 241
Time of current loop interruption (line On-Hook) during FLASH.
Setting options: 100-1500 ms
Step: 100 ms
Default setting: 100 ms
FXS routing table parameters
All parameters related to the dialed number and call routing are arranged in three
routing tables. Each table pertains to one interface: FXS, FXO and GSM.
According to the prefix of dialed number on FXS interface you can:
Bar the number to be dialed - the calling subscriber tone;
Route the call to GSM network, or to PBX through the FXO interface;
Kommentare zu diesen Handbüchern