5A transistor switch or logic signal can be used too. The pin near the telephone line connector is connected to GND of the device the second one is

Seite 3 - Upgrade

63. EasyGate Status Indication 3.1. Indication LEDs Name Meaning Power supply · Light = EasyGate is powered. · Flashes once in 2s = HW error,

Seite 4 - Packing List

7§ The called number has too many digits (more than 30). § The called number is barred. § The called subscriber line is busy. § The called subsc

Seite 5 - CONTENTS

84. SIM Card PIN protection If a SIM card is PIN-protected and the PIN is not programmed in EasyGate, GSM LED indicates the state and the PIN tone i

Seite 6 - 1. EasyGate purpose

95. Voice function Outgoing and incoming call establishing procedures for an analog telephone are described for illustration. The procedures are the

Seite 7 - 2. Installation

105.3. FAX call (only on models with fax converter) EasyGate with fax converter has ability to send and receive fax messages using analog fax Group

Seite 8 - 2.3. SIM Card Installation

116. SMS Sending Input This universal input is intended especially for reporting alarm or error statuses of any equipment provided with the appropri

Seite 9 - 2.6. Power Supply Connection

127. COM – Serial Interface The complete serial interface RS-232C on a 9-pin connector is identical with any external modem. The transmission rate r

Seite 10 - 2.8. PC Connection

137.3. FAX Transmission - PC-FAX EasyGate allows fax transmissions from your PC. However, do not confuse the PC-Fax service with a standard fax serv

Seite 11 - 3.2. Telephone Line Tones

147.6. Combination of COM Traffic with Voice Calls As already mentioned, SMS transmission can be made even during telephone calls. The SMS program i

Seite 12

Dear customer, Let us congratulate you on having purchased the EasyGate system. This new product has been developed and manufactured to provide the

Seite 13 - 4. SIM Card PIN protection

158. EasyGate Parameter Programming All EasyGate parameters have such default values that meet most users’ demands and need not be changed. To chang

Seite 14 - 5. Voice function

168.2. PC based Programming For programming, connect EasyGate to a PC with a serial cable and make sure that the EasyGate PCManager is installed. Pr

Seite 15

178.2.2. Further Data Handling Options In addition to the EasyGate memory, settings can be saved in a PC file and reloaded into the PCManager. This

Seite 16 - 6. SMS Sending Input

18· The GSM provider's name and signal strength received by EasyGate - this information helps you find the optimum signal location (the inform

Seite 17 - 7. COM – Serial Interface

198.3. Parameter Tables All programmable parameters are listed in this section. Each parameter is accompanied with the unit used, function number (i

Seite 18

20Beep after dialing end Function No.: - Select a beep to signal the end of dialing (beginning of outgoing call establishing). Setting options

Seite 19

21 Line reversal indication for call in progress Function No.: - Select call in progress signaling by telephone line polarity reversal. There is v

Seite 20

228.3.2. Routing Parameters All parameters related to the number dialed for an outgoing call are arranged in this table. According to the prefix you

Seite 21 - 8.2. PC based Programming

23Routing table enable Function No.: 20 Enable the use of the routing table with this parameter. Disabling this parameter you put the table out

Seite 22

24Extra tariff Function No.: - Pseudo tariff metering setting (tariff is based on call duration). The Extra tariff parameter defines transmi

Seite 23

User Manual Versions Version Amendments to Earlier Versions 1.00 · The User Manual applies to EasyGate FW Version 1.00D. 1.01 · New parameter for d

Seite 24 - 8.3. Parameter Tables

258.3.4. GSM & SIM Parameters GSM operator lock Function No.: - Provider blocking is set by manufacturer in EasyGate. If EasyGate is blo

Seite 25

26Serial number Function No.: - EasyGate serial number - for information only (cannot be changed). Must be used for communication with the man

Seite 26

278.3.7. Security Parameters PIN - value Function No.: 40 Fill in the PIN value for automatic PIN entering upon EasyGate power up. It is a

Seite 27

289. Troubleshooting No LED is on after power up · Check the power supply. All LEDs are on. No call is currently in progress. · EasyGate is in th

Seite 28

2910. List of Abbreviations · APN - Access Point Name – necessary for the GPRS service · CLIP - Calling Line Identification Presentation · CSD

Seite 29

3011. Technical Parameters GSM: GSM module, GSM bandwidth MC39i EGSM 900 / GSM 1800 MC55 EGSM 900 / GSM 1800 / GSM 1900 MC56 EGSM 850 / GSM 1

Seite 30

31 © 2006, 2N TELEKOMUNIKACE a.s.

Seite 31

Packing List An EasyGate delivery contains the following items: Item Number of Pieces EasyGate 1 pc Antenna for direct connection 1 pc 1) Magneti

Seite 32

CONTENTS 1. EASYGATE PURPOSE...1 1.1. BASIC F

Seite 33 - 9. Troubleshooting

1 1. EasyGate purpose 1.1. Basic Functions · The primary purpose of EasyGate is to transmit voice between a GSM network and an attached FXO-interfa

Seite 34 - 10. List of Abbreviations

22. Installation 2.1. Proper Location · EasyGate is designed for vertical mounting on suspension holes (use the mounting pattern). This position is

Seite 35 - 11. Technical Parameters

32.2. External Antenna Connection Screw the antenna enclosed into the SMA antenna connector. Tighten the antenna connector gently with your hand - n

Seite 36

42.4. Connector description SMS sending input Telephone line RJ 12, 6/2 Power supply connector DC Jack 2,1mm RS232C serial line D-Sub 9 pins 2.