2n Helios IP Automation Manual v2.8 Bedienungsanleitung Seite 31

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 43
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 30
312N TELEKOMUNIKACE a.s., www.2n.cz
®
Example
The condition is met for an activated tamper switch (device not open):
Condition.InputState: Input1=tamper; Level=0
Condition.LogicalAnd
The block helps you create groups of conditions. The block is fulfilled if allLogicalAnd
the conditions in the defined group are met.
Parameters
Condition define the list of conditions to be met. Separate the conditions with
a comma.
Example
The condition is met if conditions 1, 2 and 3 are met at the same time:
Condition.LogicalAnd: Condition=1, 2, 3
Condition.LogicalOr
The block helps you create groups of conditions. The block is fulfilled if oneLogicalOr
condition at least of the defined group is met.
Parameters
Condition define the list of conditions to be met. Separate the conditions with
a comma.
Example
The condition is met if conditions 1, 2 or 3 are met:
Condition.LogicalOr: Condition=1, 2, 3
Condition.LogicalNot
The block defines the condition to be met in case another defined conditionLogicalNot
is not met.
Seitenansicht 30