Example
Activate switch 1 if the event defined on row 2 arises and the condition defined on row
3 is met:
Action.ActivateSwitch: Switch=1; Event=2; Condition=3
Action.SetOutput
The block defines the action necessary for setting of the intercom output toSetOutput
the required level.
Parameters
Event – define the event that launches the action.
Condition – define the condition to be met to execute the action. This parameter
is optional.
Output – define the output to be set.
Valid values:
relay1 – relay 1 on basic unit
relay2 – relay 2 on basic unit
output1 – output 1 on basic unit
output2 – output 2 on basic unit
cr_relay1 – relay 1 on card reader
cr_relay2 – relay 2 on card reader
cr_output – output 1 on card reader
redled – red LED indicator
led1 – LED 1 indicator
led2 – LED 2 indicator
led3 – LED 3 indicator.
There may be different lists of valid values for different 2N Helios IP
®
models; refer to the Available Digital Inputs and Outputs subsection.
Level – define the required output level. This parameter is optional.
Valid values:
0 – output deactivation
1 – output activation (default value).
Example
Activate Output1 if the event defined on row 2 arises:
Action.SetOutput: Output=output1; Event=2
Action.BeginCall
The block defines the action necessary for establishing of an outgoing call toBeginCall
the defined telephone number, SIP URI or user number included in the intercom phone
book.